LT Valve Manual - 5.0 Recommended Storage
|

|

|
Disassemble the valve completely and detach the internal parts from the adjusting nut. See Section 2.0 DISASSEMBLY PROCEDURES for detailed instructions on valve disassembly. Remove old grease and debris from valve pocket with a solvent and inspect for wear or damage such as:
|
- Drain after testing. All equipment should be drained and lubricated after testing and prior to storage.
- All components and assemblies should be cleaned of dirt, rust, and other contaminants.
- Rust Prevention: Equipment should have exposed metallic surfaces protected with a rust inhibitor which will not become fluid and run at a temperature less than 125° F( 52° C ).
- Sealing surface protection: Exposed sealing surfaces should be protected from mechanical damage.
|
|

|
|
|
|